Use este identificador para citar ou linkar para este item: http://repositorio.ifam.edu.br/jspui/handle/4321/992
Tipo: Trabalho de Conclusão de Curso
Título: Cabeamento estruturado do centro tecnológico Harlan Julu Guerra Marcelice: um estudo de caso baseado na Norma ABNT NBR 14565:2013
Autor(es): Bezerra, Rafael Santiago
Primeiro Orientador: Fontinelle, Carlos Gomes
metadata.dc.contributor.referee1: Fontinelle, Carlos Gomes
metadata.dc.contributor.referee2: Sampaio, Ricardo Brandão
metadata.dc.contributor.referee3: Rodrigues, Marlos André Silva
Resumo: De acordo com Fey e Gauer (2014), o cabeamento estruturado surgiu devido à necessidade de organizar as instalações das redes de computadores no final dos anos 1980. Com o passar dos anos, os sistemas de telecomunicações foram se consolidando como importante componente empresarial, pois, para se ter competitividade e produtividade, é necessário uma estrutura confiável e com o mínimo de falhas possíveis. Este trabalho é sobre um estudo de caso em um sistema de cabeamento estruturado já instalado e em funcionamento de um pequeno edifício localizado no Campus Manaus Distrito Industrial do Instituto Federal de Educação, Ciência e Tecnologia do Amazonas. O estudo foi embasado na norma ABNT NBR 14565:2013, com objetivo de analisar se o sistema abordado seguia as orientações contidas na norma. Para atingir este objetivo, foi empregada a seguinte metodologia: revisão bibliográfica de normas técnicas e bibliografias correlatas, pesquisa de campo para coletar informações e, por fim, avaliação das informações obtidas segundo o que determina a norma. Neste contexto, após o levantamento no local e com as informações obtidas, foi desenvolvido um diagrama com todo o hardware localizado na Sala de Equipamento; foram identificadas, quantificadas e mapeadas em plantas baixa as Tomadas de Telecomunicação, bem como verificado o funcionamento de cada uma. Dessa forma, concluiu-se que há alguns aspectos no sistema de cabeamento estruturado que não estão de acordo com a norma em questão.
Abstract: According to Fey and Gauer (2014), structured cabling arose due to the need to organize the installations of computer networks at the end of the 1980s. Over the years telecommunications systems has been consolidating as an important business component since, to have competitiveness and productivity, and a reliable structure with minimum possible failures is required. This work is about a case study in a structured cabling system already installed and in operation, of a small building located in the Campus Manaus Industrial District (CMDI) of the Federal Institute of Education, Science and Technology of Amazonas (IFAM). The study was based on the ABNT NBR 14565: 2013 standard, in order to analyze if the system approached followed the guidelines contained in the standard. In order to reach this objective, the following methodology was used: bibliographic review of technical norms and related bibliographies, field research to collect information, and finally to evaluate if the information obtained meets what is determined in the standard. In this context, after the on-site survey and with the information obtained, a diagram was developed with all the hardware located in the Equipment Room; were identified, quantified and mapped in plants low Telecommunication Outlets (TO), as well as verified the operation of each. With this it was possible to conclude that there are some aspects in the structured cabling system that do not conform to the norm in question.
Palavras-chave: Cabeamento estruturado
ABNT
Rede de computadores
Norma
CNPq: CNPQ::CIENCIAS SOCIAIS APLICADAS::ADMINISTRACAO
Idioma: por
País: Brasil
Sigla da Instituição: Instituto Federal do Amazonas
IFAM
Administração
Instituto Federal do Amazonas
IFAM
Administração
Instituto Federal do Amazonas
IFAM
Administração
metadata.dc.publisher.department: Campus Manaus Distrito
Citação: Bezerra, Rafael Santiago. Cabeamento estruturado do centro tecnológico Harlan Julu Guerra Marcelice: um estudo de caso baseado na norma ABNT NBR 14565:2013.
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ifam.edu.br/jspui/handle/4321/992
Data do documento: 24-Jun-2019
Aparece nas coleções:Monografia_Logística

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Cabeamento estruturado do centro tecnológico Harlan Julu Guerra Marcelice_Bezerra_2019.pdf.pdfMonografia_Logística - IFAM Campus Manaus Distrito Industrial2 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.