Título: Um estudo bibliográfico da análise da substituição do fluido refrigerante R410A pelo fluido R32
Autor(es): Ramirez, John Ariel Nascimento
Primeiro Orientador: Soares, José Josimar
metadata.dc.contributor.referee1: Soares, José Josimar
metadata.dc.contributor.referee2: Monteiro, Alberto de Castro
metadata.dc.contributor.referee3: Costa, José Francisco de Caldas
Resumo: Esta pesquisa bibliografica teve como intuito analisar o coeficiente de desempenho dos fluidos refrigerantes R410A e o R32 em um ciclo de refrigeração por compressão de vapor ideal, presumindo que o coeficiente de desempenho tem tamanha importância na análise das instalações frigoríficas. Na pesquisa selecionamos os fluidos R-410A e R32, considerando que são os mais indicados para substituir o R-22, que deverá cair em total desuso no ano 2040, haja vista sua agressão à camada de ozônio. O que nos motivou a realizar essa pesquisa foi a incessante busca de encontrarmos um fluido que tivesse um baixo impacto ao meio ambiente, nossa atuação e futura formação no curso de graduação em Bacharelado em Engenharia Mecânica, o desempenho de nossas atividades na área de climatização e refrigeração. Para a elaboração desse trabalho realizamos buscas diversas, de produções científicas, que tratassem da avaliação dos parâmetros operacionais, que nos apresentasse pontos como: capacidade de refrigeração, potência consumida pelo compressor e o desempenho e descarga desenvolvida pelo compressor. O impacto que sofre o meio ambiente foi realizado por estudos que utilizavam o método TEWI, realizando uma análise do desempenho de ambos fluidos refrigerante (SILVA, 2018). De acordo com as pesquisas realizadas os testes realizados apresentam uma variação da temperatura de evaporação entre -7 e 7 °C, enquanto que a temperatura de condensação foi mantida em 41 °C. Além da temperatura de evaporação, variou-se também a frequência de operação do compressor de 45 até 60 Hz. Os resultados obtidos por SILVA (2018), demostrou que a potência consumida pelo compressor utilizando R32 aumentou de 3 a 5% quando comparada ao R410A. A capacidade de refrigeração do R32 apresentou-se, aproximadamente, de 3 a 7% maior do que para o R410A. A temperatura de descarga do compressor operando com R32 foram de, aproximadamente, 20 a 30 °C mais alta do que para o R410A. Consideradno os estudos feitos, verifica-se que o R32 apresenta uma performace superior ao R410A, considerando a menor quantidade de fluido utilizado no sistema e ao menor GWP que esse fluido apresenta
Abstract: This bibliographical research aimed to analyze the performance coefficient of refrigerants R410A and R32 in an ideal vapor compression refrigeration cycle, assuming that the performance coefficient is of such importance in the analysis of refrigeration facilities. In the research, we selected R-410A and R32 fluids, considering that they are the most indicated to replace R-22, which should fall into total disuse in the year 2040, given its aggression to the ozone layer. What motivated us to carry out this research was the incessant search to find a fluid that had a low impact on the environment, our performance and future training in the undergraduate course in Mechanical Engineering, the performance of our activities in the area of HVAC and refrigeration. For the elaboration of this work, we carried out several searches, of scientific productions, that dealt with the evaluation of the operational parameters, that presented points such as: refrigeration capacity, power consumed by the compressor and the performance and discharge developed by the compressor. The impact on the environment was carried out by studies that used the TEWI method, performing an analysis of the performance of both refrigerants. According to the research carried out, the tests performed show a variation in the evaporation temperature between -7 and 7 °C, while the condensing temperature was maintained at 41 °C. In addition to the evaporation temperature, the compressor operating frequency was also varied from 45 to 60 Hz. The results obtained by SILVA (2018), during his research, showed that the power consumed by the compressor using R32 increased from 3 to 5% when compared to R410A. The cooling capacity of R32 was approximately 3 to 7% greater than for R410A. The COP was 2 to 8% higher using R32. The discharge temperature of the compressor operating with R32 was approximately 20 to 30 °C higher than for R410A. Considering the studies carried out, it appears that R32 has a superior performance than R410A, considering the smaller amount of fluid used in the system and the smaller GWP that this fluid presents.
Palavras-chave: Engenharia mecânica
Sistema de refrigeração
Fluido refrigerante
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
Idioma: por
País: Brasil
Sigla da Instituição: Instituto Federal do Amazonas
IFAM
Engenharia Mecânica
Instituto Federal do Amazonas
IFAM
Engenharia Mecânica
Instituto Federal do Amazonas
IFAM
Engenharia Mecânica
metadata.dc.publisher.department: Campus Manaus Centro
Citação: RAMIREZ, John Ariel Nascimento. Um estudo bibliográfico da análise da substituição do fluido refrigerante R410a pelo fluido R32. 2021. 41 f. Monografia. (Graduação em Engenharia Mecânica) – Instituto Federal de Educação, Ciência e Tecnologia do Amazonas, Campus Manaus Centro, Manaus, 2021.
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ifam.edu.br/jspui/handle/4321/586
Data do documento: 20-Ago-2021
Aparece nas coleções:Monografia_Mecânica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Um estudo bibliográfico da análise da substituição do fluido refrigerante R410A pelo fluido R32Monografia_ Eng Mecânica - IFAM Campus Manaus Centro1,11 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.